Note
Action
xx0200000399
Remove the rear cover plate (A) from the base
by unscrewing the attachment screws (B).
CAUTION
Clean cover from metal residues before
opening.
Metal residues can cause shortage on the
boards which can result in hazardous failures.
3
Detailed in section
.
Remove the SMB battery.
4
Remove the SMB cover by unscrewing its at-
tachment screws.
5
Pull the battery cable through the hole in the
SMB cover.
Remove the two locknuts and washers from
the
pins
securing the board.
6
xx1700000993
Disconnect the battery cable by pressing down
the upper lip of the R2.G connector to release
the lock while pulling the connector upwards.
7
Continues on next page
Product manual - IRB 2400
157
3HAC022031-001 Revision: P
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.6.1 Replacement of SMB unit