Note
Action
Fit the two attachment screws securing the mount-
ing bracket (or brackets).
2
Fit and tighten the locking nut (or nuts).
3
Fit the Pushlok nipple (or nipples).
4
Tightening torque, brass coup-
lings 1/2": 31 Nm
Connect the Proc 3 hose from the Water and Air
unit.
CAUTION
Do not tighten the brass couplings for water and air
with excessive force.
5
Tightening torque, brass coup-
lings 1/2": 31 Nm
Connect the Proc 4 hose from the Water and Air
unit.
CAUTION
Do not tighten the brass couplings for water and air
with excessive force.
6
Only if the option
Second water
return
has been selected.
Only if the option
Second water
return
has been selected.
Tighten the locking nut, at the shop floor side.
7
Connect the hose of the shop water drain to the
water-return circuit.
8
Turn on the water supply to the Water and Air unit.
9
Activate the electrical valve.
10
This is done in order to evacuate
all air in the circuit.
First turn on and then turn off the shop water drain.
11
Tighten if there is any leakage.
Wait a couple of minutes and check for leakage.
12
Turn on the shop water drain.
13
Product manual - DressPack/SpotPack IRB 6650S
343
3HAC055424-001 Revision: C
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.4.3 Replacement of Water-return circuit
Continued
Summary of Contents for DressPack IRB6650S
Page 1: ...ROBOTICS Product manual DressPack SpotPack IRB 6650S ...
Page 8: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 206: ...This page is intentionally left blank ...
Page 228: ...This page is intentionally left blank ...
Page 346: ...This page is intentionally left blank ...
Page 358: ...This page is intentionally left blank ...
Page 384: ...This page is intentionally left blank ...
Page 386: ...This page is intentionally left blank ...
Page 388: ......
Page 389: ......