Parameters 307
Selects the unit to display for depth related values on the
keypad.
m
m
Meters
0
ft
Feet
1
Joints
Joints
2
75
Pump level control function.
Enables Pump level control function. See section
.
Disable
Disable
Disables Pump level control function.
0
Enable
Enables Pump level control function.
1
Source selection (see
on
page
-
Defines the fluid level set point for the Pump level control
function.
0.00 m, ft or
Joints
0.00...100000.00 m
Reference
10 = 1 m, ft or
Joints
Selects a mathematical function between the feedback
sources selected by parameters
and
Source1
Source1
0
Source2
1
S Source2
Sum of sources 1 and 2
2
Source1 - Source2
Source 2 subtracted from source 1
3
Source1 x Source2
Source 1 multiplied by source 2
4
Source1/Source2
Source 1 divided by source 2
5
Defines source 1 for parameter
Zero
Zero
Source not selected
0
AI1 scaled
1
AI2 scaled
2
FBA1 ref
Fieldbus adapter A reference1
3
FBA2 ref
Fieldbus adapter A reference2
4
Source selection (see
on
page
-
Defines source 2 for parameter
Zero
Zero
Source not selected
0
AI1 scaled
1
AI2 scaled
2
FBA1 ref
Fieldbus adapter A reference1
3
FBA2 ref
Fieldbus adapter A reference2
4
Source selection (see
on
page
-
No.
Name/Value
Description
Def/
FbEq16
Summary of Contents for ACS880 ESP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...