Fieldbus control through the embedded fieldbus interface (EFB) 441
Selects a reference received through the
embedded fieldbus interface as speed
reference 2.
FREQUENCY REFERENCE SELECTION
Selects a reference received through the
embedded fieldbus interface as frequency
reference 1.
Selects a reference received through the
embedded fieldbus interface as frequency
reference 2.
PCP/ESP REFERENCE SELECTION
or
Selects a reference received through the
embedded fieldbus interface as speed
reference 1 or reference 2.
OTHER SELECTIONS
EFB references can be selected as the source at virtually any signal selector parameter by
selecting
, then either
CONTROL OF RELAY OUTPUTS, ANALOG OUTPUTS AND DIGITAL INPUT/OUTPUTS
Connects bit 0 of storage parameter
to relay output RO1.
Connects bit 1 of storage parameter
to relay output RO2.
Connects bit 2 of storage parameter
to relay output RO3.
(default)
Sets the digital input/output to output mode.
Connects bit 8 of storage parameter
to digital input/output
DIO1.
Connects bit 9 of storage parameter
to digital input/output
DIO2.
Connects storage parameter
to analog output AO1.
Connects storage parameter
to analog output AO2.
SYSTEM CONTROL INPUTS
(reverts to
)
Saves parameter value changes (including
those made through fieldbus control) to
permanent memory.
Parameter
Setting for
fieldbus control
Function/Information
Summary of Contents for ACS880 ESP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...