Fault tracing 423
3385
Autophasing
Autophasing routine (see
section
on page
) has failed.
Try other autophasing modes (see
parameter
) if possible.
If the
mode is
selected, check the zero pulse
given by the encoder.
Check that the motor ID run has
been successfully completed.
Clear parameter
.
Check that the encoder is not
slipping on the motor shaft.
Check that the motor is not already
turning when the autophasing
routine starts.
Check the setting of parameter
.
4000
Motor cable overload
Calculated motor cable
temperature has exceeded
warning limit.
Check the settings of parameters
.
Check the dimensioning of the
motor cable in regard to required
load.
4210
IGBT overtemperature
Estimated drive IGBT
temperature is excessive.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-
up.
Check motor power against drive
power.
4290
Cooling
Drive module temperature is
excessive.
Check ambient temperature. If it
exceeds 40 °C (104 °F), ensure
that load current does not exceed
derated load capacity of drive. See
appropriate
Hardware Manual.
Check drive module cooling air
flow and fan operation.
Check inside of cabinet and
heatsink of drive module for dust
pick-up. Clean whenever
necessary.
42F1
IGBT temperature
Drive IGBT temperature is
excessive.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-
up.
Check motor power against drive
power.
4310
Excess temperature
Power unit module
temperature is excessive.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-
up.
Check motor power against drive
power.
4380
Excess temperature
difference
High temperature difference
between the IGBTs of
different phases.
Check the motor cabling.
Check cooling of drive module(s).
Code
(hex)
Fault
Cause
What to do
Summary of Contents for ACS880 ESP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...