Publication 1394-5.0 — May 2000
3-14
Wiring System, Axis, and Shunt Modules, and Motors (for all systems)
Terminal Block Locations for 5 and 10 kW System Module
(Series A and B)
The 5 and 10 kW system module (Series A and B) components use
IEC terminals for power connections. You will wire the system and
axis modules using the power terminal block conveniently located at
the bottom front of the system and axis modules. The maximum wire
size allowed in the terminal blocks is 3.3 mm
2
(12 AWG). To gain
access to the input power terminals, open the system module door and
look in the lower right corner. Refer to Figure 3.10 for terminal block
details.
Figure 3.10
Terminal Block for a 5 or 10 kW System Module (Series A and B)
Note:
Refer to Appendices A and B for information about three-phase
input fusing and circuit breaker information as related to the
power input. Refer to the section Connecting Your External
Shunt Resistor for information about wiring the optional shunt
resistor to the 5 and 10 kW system modules.
!
ATTENTION: To avoid personal injury and/or
equipment damage ensure installation complies with
specifications regarding wire types, conductor sizes,
branch circuit protection, and disconnect devices. The
National Electrical Code (NEC) and local codes
outline provisions for safely installing electrical
equipment.
Wire:
Description:
Connects to terminal(s):
Required (Y/N):
24V Logic
A user-supplied 24V AC rms or 24V DC power source. Refer to
Appendix A for 24V input power specifications.
W1 and W2
Y
360/480V AC
Input Power
360/480V AC, three-phase power input Refer to
Appendix A for
system specifications for rated AC input voltage, tolerance, and
source impedance.
U, V, and W
Y
Input Power
Neutral
Three-phase input neutral (present only on grounded power
configurations).
System ground bar
N
PE Ground
The 1394’s ground connection to the bonded system ground
bar on the subpanel.
PE
Y
External Shunt
Resistor
Optional 1400W external shunt resistor used to dissipate
excess regenerative energy from the system module.
DC+ and COL
N
Summary of Contents for Allen-Bradley 1394
Page 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Page 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Page 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Page 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Page 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Page 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Page 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...