Publication 1394-5.0 — May 2000
4-22
Wiring 1394 GMC and GMC Turbo Systems
For example, if your 1394 system includes three 1394 axis modules,
the 1394-DIM can control only one external drive and axis. See the
following configuration information.
Important: You can add only one 1394-DIM to a 1394 system.
Important: The system requires 360/480V AC three-phase input
power to run, even if the 1394-DIM is configured for
four external drives.
Configuration Examples
The following examples show a variety of ways to incorporate the
1394-DIM into a 1394 GMC/GMC Turbo System. The examples
show the input connections located on the bottom of a typical 1394
system and a 1394-DIM.
The example below shows two 1394 axes and two DIM output axes.
Figure 4.22
1394-DIM with Multiple Axis Modules
Number of 1394 axes:
Maximum number of
DIM-controlled axes:
4
0
3
1
2
2
1
3
0
4
Axis 2 (J5)
Auxillary Encoder Input
Axis 3 (J10)
Auxillary Encoder Input
Axis 0 (J5)
Motor Resolver Feedback Input
Axis 1 (J6)
Motor Resolver Feedback Input
Axis 2 (J7)
1394 DIM Plug
Axis 3 (J10)
1394 DIM Plug
DIM Axis A
Axis 2 on 1394
DIM Axis B
Axis 3 on 1394
Axis 0
Axis 1
1394 GMC or GMC Turbo System
1394
x-AMxx
1394
x-AMxx
1394-DIM
1
7
1
7
Summary of Contents for Allen-Bradley 1394
Page 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Page 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Page 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Page 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Page 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Page 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Page 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...