Publication 1394-5.0 — May 2000
Wiring System, Axis, and Shunt Modules, and Motors (for all systems)
3-11
7. Without removing the circuit board, unplug the jumper and move
it to the ungrounded power distribution position. Refer to the
figure below for the jumper positions.
Figure 3.7
22 kW System Module Jumper Positions
8. Re-install the input wiring board.
9. Re-install the upper and lower input wiring board screws. Refer
to Figure 3.5 for the location of the screws.
10. Re-connect both ends of the input wiring board ribbon cable.
Refer to Figure 3.5 for the location of the ribbon cable.
11. Close the system module door.
12. Go to Grounding Your 1394 System.
Factory default jumper
position for a grounded
configuration
Jumper position for an
ungrounded power
configuration
Front edge
of board
Front edge
of board
DO NOT REMOVE CIRCUIT
BOARD FROM 1394
Summary of Contents for Allen-Bradley 1394
Page 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Page 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Page 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Page 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Page 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Page 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Page 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...