Publication 1394-5.0 — May 2000
Interconnect and CE Diagrams
B-17
The example below shows 1394 (Series A and B) axis modules (no
internal brake or thermal switch filter). Separate 24V DC isolation
power supply and relay (CR2) are recommended.
Figure B.10
Isolated Series E-Stop
Axis 0
Axis 1
Axis 2
Axis 3
1394 GMC Input Wiring Board
1394
x-SJTxx-C
1394
x-SJTxx-C-RL
AND
1394
x-SJTxx-T
1394
x-SJTxx-T-RL
TB2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
TB1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
21
22
23
24
25
26
27
24V DC
Power Supply
+24V DC
24V DC com
CR2
24V AC/DC
or
120V AC,
50/60 HZ
STOP
START
CR1
CR1
CR1
M1
CR2
Note: 120V AC (50 or 60 Hz) power may be used in place of a 24V DC power supply for motor thermal switch circuits.
Motor Thermal
Switch
Drive OK
Relay
TB1
TB2
1394-AM
xx
4 3 2 1
4 3
4 3
2 1
TB1
TB2
1394-AM
xx
4 3 2 1
4 3
4 3
2 1
TB1
TB2
1394-AM
xx
4 3 2 1
4 3
4 3
2 1
TB1
TB2
1394-AM
xx
4 3 2 1
4 3
4 3
2 1
Summary of Contents for Allen-Bradley 1394
Page 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Page 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Page 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Page 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Page 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Page 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Page 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...