Publication 1394-5.0 — May 2000
Installing Your 1394 (applies to all systems)
2-15
Mounting the Shunt Module
The procedures in this section assume you have prepared your panel
and understand how to bond your system. To mount your 1394 Shunt
Module:
1. Install the top mounting fasteners on the subpanel for the shunt
module. The heads of both fasteners should be at least 6.35 mm
(0.25 in.) from the panel. Make sure the fasteners are properly
bonded to the subpanel. Refer to Bonding Your System for more
information.
2. Hang the 1394 Shunt Module on the two fasteners.
3. Install the lower fasteners for the shunt module.
4. Tighten all mounting fasteners.
Summary of Contents for Allen-Bradley 1394