Publication 1394-5.0 — May 2000
B-28
Interconnect and CE Diagrams
Figure B.22
1394-GE15 Cable Connections
1
Customer supplied 5V DC power source is required for encoder board whether encoder supply voltage is
5V or not.
Figure B.23
1394-GR04 Cable Connections
7
1
2
3
4
5
6
8
9
12
10
11
Black
Yellow
White
Black
Green
Black
Blue
Black
Red
Black
Shield
NC
Strobe
A High
A Low
B High
B Low
Z High
Z Low
+5V Out
Common Out
1394 Encoder
Feedback Connector
Flying Leads to
Incremental Encoder or
Customer-Supplied Termination
NC
Shield
Red
Black
+5V Input
Common In
Encoder Power
(ENC. PWR)
Cable is Belden 9505
Cable is Belden 9501
1
4100-REC Axis 0 or
Axis 1 Connector
9
2
4
10
5
11
6
12
9
7
1
2
3
4
5
6
12
12
10
11
Encoder Power
(ENC. PWR)
+5V DC Com
+5V DC
1394 GMC or GMC Turbo
Encoder Feedback Connector
Cable is Belden 9504
Cable is Belden 9501
Black
Red
White
Black
Green
Black
Blue
Black
Red
Black
Summary of Contents for Allen-Bradley 1394
Page 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Page 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Page 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Page 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Page 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Page 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Page 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...