User Manual
3onedata proprietary and confidential
Copyright © 3onedata Co., Ltd.
80
Port Redirect
Indicates the port redirect operation of the ACE. Frames matching the ACE are
redirected to the port number. The allowed values are Disabled or a specific port
number. When Disabled is displayed, the port redirect operation is disabled.
Mirroring
Specify the mirror operation of this port. Frames matching the ACE are mirrored to the
destination mirror port. The allowed values are:
Enable: Frames received on the port are mirrored.
Disable: Frames received on the port are not mirrored.
The default value is "Disabled".
Counter
The counter indicates the number of times the ACE was hit by a frame.
Modification Buttons
You can modify each ACE (Access Control Entry) in the table using the following
buttons:
Add: Inserts a new ACE before the current row.
Edit: Edits the ACE row.
Up: Moves the ACE up the list.
down: Moves the ACE down the list.
Delete: Delete ACE.
Add: The lowest plus sign adds a new entry at the bottom of the ACE listings.
Buttons
Auto-refresh: Check this box to refresh the page automatically. Automatic refresh
occurs every 3 seconds.
Refresh: Click to refresh the page; any changes made locally will be undone.
Clear: Click to clear the counters.
Clear all: click to delete all ACEs.