User Manual
3onedata proprietary and confidential
Copyright © 3onedata Co., Ltd.
191
Maintenance
Enable/disable of loss measurement availability maintenance.
Loss Measurement Availability Status
Near Avail Count
Near end availability count.
Far Avail Count
Far end availability count.
Near Unavail Count
Near end unavailability count.
Far Unavail Count
Far end unavailability count.
Near State
Near end availability state.
Far State
Far end availability state.
Loss Measurement High Loss Interval
Enable
Enable/disable of loss measurement high loss interval.
FLR Threshold
High Loss Interval frame loss ratio threshold in per mille.
Consecutive Interval
High Loss Interval consecutive interval (number of measurements).
Loss Measurement High Loss Interval Status
Near Count
Near end high loss interval count (number of measurements where availability state is
available and FLR is above high loss interval FLR threshold.
Far Count
Far end high loss interval count (number of measurements where availability state is
available and FLR is above high loss interval FLR threshold.
Near Consecutive Count
Near end high loss interval consecutive count.