User Manual
3onedata proprietary and confidential
Copyright © 3onedata Co., Ltd.
57
CRCErrors
Total number of packets received. Eight-bit byte with length (excluding the frame part,
but including FCS octets) between 64 and 1518, but there is an integer (FCS error)
bad frame check sequence (FCS) of eight-bit byte or a bad FCS eight-bit byte which is
not an integer (alignment error).
Undersize
The total number of packets received that were less than 64 octets.
Oversize
The total number of packets received that were longer than 1518 octets.
Frag.
The number of frames which size is less than 64 octets received with invalid CRC.
Jabb.
The number of frames which size is larger than 64 octets received with invalid CRC.
Coll.
The best estimate of the total number of collisions on this Ethernet segment.
Utilization
The best estimate of the mean physical layer network utilization on this interface during
this sampling interval, in hundredths of a percent.
Buttons
Auto-refresh: Check this box to refresh the page automatically. Automatic refresh
occurs every 3 seconds.
Refresh: Click to refresh the page immediately.
: Updates the table starting from the first entry in the Alarm Table, i.e. the entry
with the lowest ID.
: Updates the table, starting with the entry after the last entry currently displayed.
4.8.7 Alarm Monitoring
This page provides an overview of RMON Statistics entries. Each page shows up to
99 entries from the Alarm table, default being 20, selected through the "entries per
page" input field. When first visited, the web page will show the first 20 entries from the