User Manual
3onedata proprietary and confidential
Copyright © 3onedata Co., Ltd.
55
Coll.
The best estimate of the total number of collisions on this Ethernet segment.
64
The total number of packets (including bad packets) received that were 64 octets in
length.
65~127
The total number of packets (including bad packets) received that were between 65 to
127 octets in length.
128~255
The total number of packets (including bad packets) received that were between 128
to 255 octets in length.
256~511
The total number of packets (including bad packets) received that were between 256
to 511 octets in length.
512~1023
The total number of packets (including bad packets) received that were between 512
to 1023 octets in length.
1024~1588
The total number of packets (including bad packets) received that were between 1024
to 1588 octets in length.
Buttons
Auto-refresh: Check this box to refresh the page automatically. Automatic refresh
occurs every 3 seconds.
Refresh: Click to refresh the page immediately.
: Updates the table starting from the first entry in the Alarm Table, i.e. the entry
with the lowest ID.
: Updates the table, starting with the entry after the last entry currently displayed.
4.8.6 History Monitoring
This page provides an overview of RMON History entries. Each page shows up to 99
entries from the History table, default being 20, selected through the "entries per page"