243
Press "Start" to run diagnostics. This will take approximately 5 seconds. If all ports are
selected, this can take approximately 15 seconds. When completed, the page
refreshes automatically, and you can view the cable diagnostics results in the cable
status table. Please note that VeriPHY is only applicable to cables with a length of 7-
140m.
10 and 100 Mbps ports will be linked down while running VeriPHY. Therefore, running
VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop
responding until VeriPHY is complete.
Port
The port where you are requesting VeriPHY Cable Diagnostics.
Cable Status
Port:
Switch port number.
pair:
The status of the cable pair.
-
OK - Correctly terminated pair
-
Open - Open pair
-
Short - Shorted pair
-
Short A - Cross-pair short to pair A
-
Short B - Cross-pair short to pair B
-
Short C - Cross-pair short to pair C
-
Short D - Cross-pair short to pair D
-
Cross A-Abnormal cross-pair coupling with pair A