200
Instance Data
ERPS ID
The ID of the Protection group.
Port 0
This will create a Port 0 of the switch in the ring.
Port 1
This will create "Port 1" of the switch in the Ring. As interconnected sub-ring will have
only one ring port, "Port 1" is configured as "0" for interconnected sub-ring. "0" in this
field indicates that no "Port 1" is associated with this instance
Port 0 SF MEP
The Port 0 Signal Fail reporting MEP.
Port 1 SF MEP
The Port 1 Signal Fail reporting MEP. As only one SF MEP is associated with
interconnected sub-ring without virtual channel, it is configured as "0" for such ring
instances. "0" in this field indicates that no Port 1 APS MEP is associated with this
instance.
Port 0 APS MEP
The Port 0 APS PDU handling MEP.
Port 1 APS MEP
The Port 1 APS PDU handling MEP. As only one APS MEP is associated with
interconnected sub-ring without virtual channel, it is configured as "0" for such ring
instances. "0" in this field indicates that no Port 1 APS MEP is associated with this
instance.
Ring Type
Type of Protecting ring. It can be either major ring or sub-ring.
Instance Configuration
Configured
Red: This ERPS is only created and has not yet been configured - is not active.
Green: This ERPS is configured - is active.
Guard Time
Guard timeout value to be used to prevent ring nodes from receiving outdated R-APS
messages.