User Manual
3onedata proprietary and confidential
Copyright © 3onedata Co., Ltd.
193
Proprietary: Proprietary way with follow-up packets to transmit 1DM/DMR.
Counter
This is only used if the 'Ended' is configured to single ended.
Round trip: The frame delay calculated by the transmitting and receiving timestamps
of initiators. Frame Delay = RxTimeb-TxTimeStampf
Flow: The frame delay calculated by the transmitting and receiving timestamps of
initiators and remotes. Frame Delay = (RxTimeb-TxTimeStampf)-(TxTimeStampb-
RxTimeStampf)
Gap
The gap between transmitting 1DM/DMM PDU in 10ms. The range is 10 to 65535.
Count
The number of last records to calculate. The range is 10 to 2000.
Unit
The time resolution.
Synchronized
Enable to use DMM/DMR packet to calculate dual ended DM. If the option is enabled,
the following action will be taken. When DMR is received, two-way delay (roundtrip or
flow) and both near-end-to-far-end and far-end-to-near-end one-way delay are
calculated. When DMM or 1DM is received, only far-end-to-near-end one-way delay is
calculated.
Counter Overflow Action
The action to counter when overflow happens.
Delay Measurement State
Tx
The accumulated transmit count - since last 'clear'.
Rx
The accumulated receive count - since last 'clear'.
Rx Timeout
The accumulated receive timeout count for two-way only - since last 'clear'.
Rx Error
The accumulated receive error count - since last 'clear'. This is counting if the frame
delay is larger than 1 second or if far end residence time is larger than the round trip
time.