Chapter 45 NLB
XGS4600 Series User’s Guide
430
Figure 344
Advanced Application > NLB
The following table describes the labels in this screen.
Table 194 Advanced Application > NLB
LABEL
DESCRIPTION
MAC forwarding
Name
Enter a descriptive name for identification purposes for this rule.
MAC Address
Enter a multicast or unicast MAC address of a cluster.
The last binary bit of the first octet pair in a multicast MAC address must be 1. For example, the
first octet pair 00000001 is 01 and 00000011 is 03 in hexadecimal, so 01:00:5e:00:00:0A and
03:00:5e:00:00:27 are valid multicast MAC addresses.
The last binary bit of the first octet pair in a unicast MAC address must be 0. For example, the
first octet pair 00000000 is 00 and 00000010 is 02 in hexadecimal, so 00:00:5e:00:00:0A and
02:00:5e:00:00:27 are valid unicast MAC addresses.
VID
Enter the VLAN identification number. If you do not have a specific target VLAN, enter 1.
The Switch will forward traffic to ports in this VLAN group.
Port
Enter the ports to which you want the Switch to forward the incoming NLB traffic.
You can enter multiple ports separated by (no space) comma (,) or hyphen (–). For example,
enter “3–5” for ports 3, 4, and 5. Enter “3,5,7” for ports 3, 5, and 7.
In stacking mode, the first number represents the slot and the second the port number. Enter 1/
1-1/24,2/23 for ports 1 to 24 for the Switch in slot 1 and port 23 for the Switch in slot 2, for
example.
Add
Click
Add
to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the
Save
link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
Clear
Click
Clear
to reset the fields to the factory defaults.
Index
This field displays the index number of the rule.
Name
This field displays the descriptive name of the rule.
MAC Address
This field displays the multicast or unicast MAC address of this rule.
VID
This field displays the VLAN group identification number.
Port
This field displays the ports to which the Switch will forward the incoming NLB traffic.
Содержание XGS4600 Series
Страница 24: ...24 PART I User s Guide ...
Страница 44: ...44 PART II Technical Reference ...
Страница 180: ...Chapter 13 Spanning Tree Protocol XGS4600 Series User s Guide 180 Figure 145 MSTP and Legacy RSTP Network Example ...
Страница 189: ...Chapter 16 Mirroring XGS4600 Series User s Guide 189 Figure 150 Advanced Application Mirroring Standalone Mode ...
Страница 244: ...Chapter 22 Policy Rule XGS4600 Series User s Guide 244 Figure 189 Policy Example EXAMPLE ...
Страница 277: ...Chapter 25 Multicast XGS4600 Series User s Guide 277 Figure 215 Advanced Application Multicast MVR Standalone Mode ...
Страница 559: ...Chapter 59 Access Control XGS4600 Series User s Guide 559 Figure 460 Example Lock Denoting a Secure Connection EXAMPLE ...
Страница 586: ...Chapter 69 Configure Clone XGS4600 Series User s Guide 586 Figure 479 Management Configure Clone Standalone Mode ...
Страница 587: ...Chapter 69 Configure Clone XGS4600 Series User s Guide 587 Figure 480 Management Configure Clone Stacking Mode ...
Страница 594: ...Chapter 71 Port Status XGS4600 Series User s Guide 594 Figure 485 Management Port Status Port Details Standalone Mode ...
Страница 604: ...604 PART III Troubleshooting and Appendices ...