![ZyXEL Communications XGS4600 Series Скачать руководство пользователя страница 361](http://html1.mh-extra.com/html/zyxel-communications/xgs4600-series/xgs4600-series_user-manual_945493361.webp)
Chapter 35 Error-Disable
XGS4600 Series User’s Guide
361
35.5 Error-Disable Detect Configuration
Use this screen to have the Switch detect whether the control packets exceed the rate limit configured
for a port and configure the action to take once the limit is exceeded. Click the
Click Here
link
next to
Errdisable Detect
link in the
Advanced Application
>
Errdisable
screen to display the screen as shown.
Figure 287
Advanced Application > Errdisable > Errdisable Detect
The following table describes the labels in this screen.
*
Use this row to make the setting the same for all ports. Use this row first and then make
adjustments to each port if necessary.
Changes in this row are copied to all the ports as soon as you make them.
Rate Limit (pkt/s) Enter a number from 0 to 256 to specify how many control packets this port can receive or
transmit per second.
0
means no rate limit.
You can configure the action that the Switch takes when the limit is exceeded.
Apply
Click
Apply
to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the
Save
link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Cancel
Click
Cancel
to begin configuring this screen afresh.
Table 160 Advanced Application > Errdisable > CPU protection (continued)
LABEL
DESCRIPTION
Table 161 Advanced Application > Errdisable > Errdisable Detect
LABEL
DESCRIPTION
Cause
This field displays the types of control packet that may cause CPU overload.
*
Use this row to make the setting the same for all entries. Use this row first and then make
adjustments to each entry if necessary.
Changes in this row are copied to all the entries as soon as you make them.
Active
Select this option to have the Switch detect if the configured rate limit for a specific control
packet is exceeded and take the action selected below.
Mode
Select the action that the Switch takes when the number of control packets exceed the rate
limit on a port, set in the
Advanced Application
>
Errdisable
>
CPU protection
screen.
•
inactive-port
– The Switch disables the port on which the control packets are received.
•
inactive-reason
– The Switch drops all the specified control packets (such as BPDU) on the
port.
•
rate-limitation
– The Switch drops the additional control packets the ports has to handle in
every one second.
Содержание XGS4600 Series
Страница 24: ...24 PART I User s Guide ...
Страница 44: ...44 PART II Technical Reference ...
Страница 180: ...Chapter 13 Spanning Tree Protocol XGS4600 Series User s Guide 180 Figure 145 MSTP and Legacy RSTP Network Example ...
Страница 189: ...Chapter 16 Mirroring XGS4600 Series User s Guide 189 Figure 150 Advanced Application Mirroring Standalone Mode ...
Страница 244: ...Chapter 22 Policy Rule XGS4600 Series User s Guide 244 Figure 189 Policy Example EXAMPLE ...
Страница 277: ...Chapter 25 Multicast XGS4600 Series User s Guide 277 Figure 215 Advanced Application Multicast MVR Standalone Mode ...
Страница 559: ...Chapter 59 Access Control XGS4600 Series User s Guide 559 Figure 460 Example Lock Denoting a Secure Connection EXAMPLE ...
Страница 586: ...Chapter 69 Configure Clone XGS4600 Series User s Guide 586 Figure 479 Management Configure Clone Standalone Mode ...
Страница 587: ...Chapter 69 Configure Clone XGS4600 Series User s Guide 587 Figure 480 Management Configure Clone Stacking Mode ...
Страница 594: ...Chapter 71 Port Status XGS4600 Series User s Guide 594 Figure 485 Management Port Status Port Details Standalone Mode ...
Страница 604: ...604 PART III Troubleshooting and Appendices ...