13.2.5 ORP Alarm - High Alert
The high alert alarm sets an alarm to deactivate the
controller in the event of an ORP reading that is out of
high range. This could be an indication of a mechanical
malfunction in the feeding system.
On the CHEMLINK ORP setup screen, select the HI
ALERT values. Use the UP and DOWN arrows to adjust
the high alert values. Click SAVE when finished.
ChemLink
Home
Menu OneTouch
Help
Back
Status
Thu June, 2011 3:03 PM
ChemLink 1 ORP
Status
Feeder
LIQUID
Feed TM
15 SEC
Delay OT
45 Min
Set Point
7.0
High Alert
8.0
Adjust
Low Alert
6.0
Page
Down
Page
Up
Save
Orp
pH
Default
950
Range
350 to 950
13.2.6 ORP Alarm - Low Alert
The low alert alarm sets an alarm to deactivate the
controller in the event of an ORP reading that is out of
low range. This could be an indication of a mechanical
malfunction in the feeding system.
On the CHEMLINK ORP setup screen, select the LOW
ALERT values. Use the UP and DOWN arrows to adjust
the low alert values. Click SAVE when finished.
ChemLink
Home
Menu OneTouch
Help
Back
Status
Thu June 23, 2011 3:03 PM
ChemLink 1 ORP
Status
Feeder
LIQUID
Feed TM
15 SEC
Delay OT
45 Min
Set Point
7.0
High Alert
8.0
Adjust
Low Alert
6.0
Page
Down
Page
Up
Save
Orp
pH
Default
100
Range
100 to 650
13.2.7 Wait or Stop pH
On the CHEMLINK ORP setup screen, select the WAIT
PH/STOP PH entry. Use the UP and DOWN arrows
to adjust the wait/stop pH entry. Click SAVE when
finished.
ChemLink
Home
Menu OneTouch
Help
Back
Status
Thu June, 2011 3:03 PM
ChemLink 1 ORP
Status
Wait pH
NO
Stop pH
YES
Next Clean
Dec 22
Adjust
Page
Down
Page
Up
Save
Orp
pH
Wait for pH:
YES= ORP will not feed at the same time as pH.
NO= ORP will feed regardless of when pH feeds.
Default= YES
Stop for pH:
YES= ORP will not feed if the pH is out of range.
NO= ORP will feed regardless of pH.
Default= YES
Page 56