13.2.1 ORP Feeder Type
Depending on your installation, the iAquaLink may
display the following feeders:
▪
NONE - Default setting.
▪
SALT - For salt water chlorinators.
▪
ERO LP - Non typical application.
▪
MBV - Non typical application.
▪
ERO HP - Non typical application.
▪
LIQUID - For liquid peristaltic pumps.
▪
GRAN - For Polaris
®
G1000 dichor feeders.
On the CHEMLINK ORP setup screen, select the
FEEDER type. Use the UP and DOWN arrows to select
the feeder type. Click SAVE when finished.
ChemLink
Home
Menu OneTouch
Help
Back
Status
Thu June 23, 2011 3:03 PM
ChemLink 1 ORP
Status
Feeder
LIQUID
Feed TM
15 SEC
Delay OT
45 Min
Set Point
7.0
High Alert
8.0
Adjust
Page
Down
Page
Up
Save
Orp
pH
13.2.2 ORP Feeder Times
The feeders times, sets the amount of time the controller
activates the feeder per dose.
On the CHEMLINK ORP setup screen, select the FEED
TM values. Use the UP and DOWN arrows to adjust the
feed times values. Click SAVE when finished.
ChemLink
Home
Menu OneTouch
Help
Back
Status
ChemLink 1 ORP
Status
Feeder
LIQUID
Feed TM
15 SEC
Delay OT
45 Min
Set Point
7.0
High Alert
8.0
Adjust
Page
Down
Page
Up
Save
Orp
pH
Thu June 23, 2011 3:03 PM
Type
ERO LP/MBV/ERO HP
Liquid
Default
Do not use
30 Sec
Range
.05 Sec to
CONT
13.2.3 ORP Delay On Time
On the CHEMLINK ORP setup screen, select the
DELAY OT time. Use the UP and DOWN arrows to
adjust the delay on time. Click SAVE when finished.
ChemLink
Home
Menu OneTouch
Help
Back
Status
Thu June 23, 2011 3:03 PM
ChemLink 1 ORP
Status
Feeder
LIQUID
Feed TM
15 SEC
Delay OT
45 Min
Set Point
7.0
High Alert
8.0
Adjust
Page
Down
Page
Up
Save
Orp
pH
Type
Salt
ERO LP/
MBV/
ERO HP
Liquid
Gran
Default Overfeed
Off
Do not
use
10 Min
30 Min
Range
1-99 Min 1-99 Min
OVERFEED: Salt only. Will alarm and not feed if ORP
has activated for too long, preventing damage to the
cell.
FEED DELAY: Sets the amount of time the controller
waits to dose the pool again.
13.2.4 ORP Setpoint
This setting specifies the level of sanitizer to be
maintained.
On the CHEMLINK ORP setup screen, select the SET
POINT values. Use the UP and DOWN arrows to adjust
the set point values. Click SAVE when finished.
ChemLink
Home
Menu OneTouch
Help
Back
Status
ChemLink 1 ORP
Status
Feeder
LIQUID
Feed TM
15 SEC
Delay OT
45 Min
Set Point
7.0
High Alert
8.0
Adjust
Page
Down
Page
Up
Save
Orp
pH
Thu June 23, 2011 3:03 PM
Default
650
Range
200 to 900
Page 55