9.8.1 To Set Up Device Runtime
MENU > SYSTEM SETUP > DEVICE RUNTIME
On the SYSTEM SETUP screen, click the DEVICE
RUNTIME button to display the screen below. On this
screen, click the device of your choice. Enter your new
time using the numeric keypad and click the ENTER
button when finished.
Use PAGE DOWN/PAGE UP to view additional
devices. Click the SAVE button to save the updated
settings and to exit this screen.
Home
Menu OneTouch
Help
Back
Status
Power
Number of Spa Remotes
Device Run Time
Spa
2:00
OneTouch 1
:30
OneTouch 2
:45
OneTouch 3
Off
OneTouch 4
Off
OneTouch 5
Off
OneTouch 6
Off
Aux 1
3:00
Devices
Hrs/Min
Page
Down
Page
Up
Save
7 8
9
4
5
6
1
2 3
0
Clear
Enter
Set Time:
30
Thu June 23, 2011 3:03 PM
9.9
Maintain Temp
NOTE
Maintain Temp is designed to operate outside (before
or after) the normal filtration pump times.
The MAINTAIN TEMP menu provides the ability to
specify how often the filter pump is turned on to sample
the water temperature. This feature allows for the
sampling interval to be set to one (1), two (2), or four
(4) hours. The default value will be two (2) hours.
9.9.1 To Set Up Maintain Temp
Note that the MAIN TAIN TEMP will run the pump
for the chosen body of water to keep the water at the
desired temperature, if this function is ON and the
heater/chiller (if installed) is enabled. The system will
au to mat i cal ly turn on the pump every couple of hours
for just enough time to test the water temperature.
If the temperature meets the set point, the pump will
return to off. If the measured temperature is different
than the set tem per a ture, the pump will stay on and
the heater/chiller will operate long enough to bring the
wa ter to the set tem per a ture.
MENU > SYSTEM SETUP > MAINTAIN TEMP
On the SET TEMPERATURE screen, click the
MAINTAIN TEMP button to display the MAINTAIN
TEMP screen.
Home
Menu OneTouch
Help
Back
Status
Maintain Temp
Save
Start
Heat
Stop
8:00 PM
10:00 PM
Sample Status
Dis
Ena
Pool
Spa
10:00 AM
7:00 PM
–
2 Hrs
Set:
:05
PM
7 8 9
4 5 6
1 2 3
0
Clear Enter
Thu June 23, 2011 3:03 PM
Schedule the MAINTAIN TEMP as follows:
▪
On the MAINTAIN TEMP screen, click the START time
of the selected equipment, and use the numeric keypad
to enter the new time.
▪
If you make a mistake, click the CLEAR button and
re-enter new time again. Click the ENTER button when
fi nished.
▪
To set the stop time, click the STOP time of the selected
equipment and use the numeric keypad to enter the new
time.
▪
To set the sample time, click the SAMPLE time of the
selected equipment and use the numeric pad to enter
the new sampling interval.
▪
Click the ON/OFF button to enable or disable the
MAINTAIN TEMP schedule of the selected equipment.
▪
Click SAVE when fi nished.
9.10 RS InterLink
NOTE
This equipment may not be part of your system.
Please check with your installer.
The RS InterLink menu allows a single controller to
access two (2) main power centers on the AquaLink RS
system.
For ease of operation, it is suggested that each power
center be given a custom product name that would allow
a user to identify to which power center the controller is
connected. During operation, this name will appear on
the iAquaLink Date/Time screen.
NOTE
The RS InterLink feature must be enabled before it
may be accessed on the OTHER EQUIPMENT ON/
OFF screen.
Page 34
iAquaLink™ Web Connect Device for AquaLink
®
& PDA Control Systems
|
Owner's Manual
ENGLISH