Preset 3:
For the pool pump, if DIP switch S1-1 is ON, then the
default label for this preset is CLEANER. Anytime
the cleaner mode is turned on the pump will run at the
speed setting of this preset. If DIP switch S1-1 is OFF,
then the default label for this preset is SPEED3.
For the spa pump the default label is SPEED3.
Preset 4:
The default label is SPEED4.
Preset 5:
For the pool pump the default label is POOL HEAT.
When the pool heater is enabled the pump will run at
this speed.
For the spa pump the default label is SPEED5.
Preset 6:
For the pool pump the default label is SPEED6.
For the spa pump the default label is SPA HEAT. When
the spa heater is enabled the pump will run at this speed.
Preset 7:
For the pool pump, if the system is in the SOLAR
HEAT mode or the HEAT PUMP mode then the
pump will run at this preset speed. If the system is not
configured for solar heat or a heat pump then the default
label will be SPEED7.
For the spa pump the default label is SPEED7.
Preset 8:
For the pool pump, when the In-Floor clean mode is
enabled and the pump is running, it will be running at
this preset speed.
For the spa pump the default label is SPEED8.
11.10 Variable Speed Pump Detail
Operation
11.10.1 Filtration Mode
a) Manual operation
setting speeds by turning on auxiliaries
that have speeds assigned to them.
1. The pump is set to the speed that is assigned
to the auxiliary. The exception to this rule will
be when the pool/spa heater, solar heat, or heat
pump is ON. To protect the heater, solar panels,
or heat pump we do not allow the user to select
a lower speed than the heater and solar speed
settings while they are ON.
2. If you have several auxiliaries that have speeds
assigned and if they are all ON, and you then turn
OFF one of the auxiliaries, the pump will be set
to the highest speed that is assigned to any of the
auxiliaries that are ON. Once again, if the pool/
spa heater, solar heat, or heat pump is ON, we do
not allow the user to select a lower pump speed.
adjusting speeds from the “other
Devices” screen.
1. On this screen, you can adjust the pump to the
desired speed, however the pump will only stay at
the speed for that manual ON time. The manual
adjust pump speeds are temporary, and not saved
- so if you turn the pump OFF and then ON
again, the pump will revert back to the default
values.
b) Programmed operation
The pump will go to the speed programmed.
However, if the pool/spa heater, solar heat, or
heat pump is on, the pump will not go any lower
than the pool/spa heater, solar heat, or heat pump
speed setting.
c) Freeze Protection
In the freeze protect mode the pump will turn
ON and be set to at least the freeze protect
speed. If the filter pump speed is higher than the
freeze protect speed, then the pump will run at
the filtration speed. Also, if speeds have been
assigned to auxiliaries and if those auxiliaries
are freeze protected, the pump will be set to the
highest of the speeds.