11.10.2 Auxiliary Pump Mode
a) Manual operation
setting speeds by turning on auxiliaries
that have speeds assigned to them.
1. The speed assigned to the auxiliary that was
pressed takes precedence. For example, if the
pump is at 3000 RPM, and then AUX 1 is
pressed, the pump will switch to the speed that
is assigned to AUX 1 regardless of whether the
speed is higher or lower than the speed that the
pump is currently running at. So, referring to
the table below, if all of the auxiliaries are OFF
and then AUX 3 is turned ON the pump will go
to 3000 RPM. Then if AUX 2 is turned ON the
pump switches to 2000 RPM.
2. However, if you have several auxiliaries ON
and all of them have a speed assigned to them,
what speed does the pump go to when you turn
OFF one of the auxiliaries? The pump will
switch to the highest speed that is assigned to the
auxiliaries. For example, referring to the table
below, if all 3 auxiliaries are ON and the pump
is at 1000 RPM, what speed will the pump go to
when AUX 1 is turned OFF? The answer is 3000
RPM, the highest speed that is assigned to the
auxiliaries that are ON.
auX #
sPeeD assIGneD To auX
1
1000 RPM
2
2000 RPM
3
3000 RPM
setting speeds from the VsP adjust/set
speed menu (accessed from the other
devices screen).
1. Regardless of what speed is ON, the pump will
switch to the speed depending on which one of
the 8 buttons on this screen is pressed.
b) Programmed operation
Programming pump sPeeDs.
1. The pump will go to the speed that is being
turned ON by the program regardless of what the
speed currently is. If a program time ends and
there are other programs overlapping, the pump
will go to the highest programmed speed.
Programming auXIlIarIes that have
speeds assigned to them.
1. The pump will go to the speed that is assigned to
the auxiliary that is being turned ON, regardless
of the current speed. If several programs are
overlapping for auxiliaries that have speed
assigned to them, the pump will operate at the
speed of the auxiliary that was most recently
turned ON.
2. If several programs are overlapping for
auxiliaries that have speeds assigned to them, and
then one of the programs end, then the pump will
switch to the highest speed of all the auxiliaries
that are ON.
Page 50
iAquaLink™ Web Connect Device for AquaLink
®
& PDA Control Systems
|
Owner's Manual
ENGLISH