9.10.1 To Set Up RS Intelink
MENU > SYSTEM SETUP > RS INTERLINK
On the SYSTEM SETUP screen, click the RS
INTERLINK button and the INTERLINK SETUP
screen will be displayed. On this screen, click the
ENABLED button to set the RS INTERLINK.
If you want to rename the power center, click the
CUSTOM LABEL to display the keyboard screen.
NOTE
By factory default the power center(s) is labeled as
power center "B". When labeling remember you are
creating a label for the power center to which you will
be switching.
Home
Menu OneTouch
Help
Back
Status
Photos
Power
Enabled
Custom Label
InterLink Setup
Custom Label
Q W E R T Y U I O P
A S D F G H J K L
Z X C V B N M
Shift
Space
Number Pad
Save
Back
POWER CENTER B
Thu June 23, 2011 3:03 PM
Thu June 23, 2011 3:03 PM
Home
Menu OneTouch
Help
Back
Status
9.11 Freeze Protection
NOTE
By factory default the filter pump circuit is freeze
protected and cannot be removed from the freeze
protection.
Use Freeze Protection menu to assign freeze protection
to your pool and spa equipment. When a piece of
equipment is assigned to freeze protection, it will turn
on when the iAquaLink detects freezing conditions. The
main filter pump is freeze-protected as a default.
Activation temperature can be adjusted between 34°F
(1°C) and 42°F. Default freeze protection activation
temperature is 38º F (3°C) and will deactivate within
two degrees..
9.11.1 To Set Up Freeze Protection
The FREEZE PROTECT menu can be accesed on
the SYSTEM SETUP screen as well as the LABEL
AUXILIARES screen.
MENU > SYSTEM SETUP > FREEZE PROTECT
Click the FREEZE PROTECT button on the SYSTEM
SETUP menu to display the FREEZE PROTECT menu.
Home
Menu OneTouch
Help
Back
Status
Freeze Protect
Freeze Protect
Page
Down
Page
Up
Save
Filter Pump
Spa
X
Solar Heat
Rockfall
Aux 1
Aux 2
Aux 3
Devices
On/Off
7 8
9
4
5
6
1
2 3
0
Clear
Enter
Freeze Temp:
38
Thu June 23, 2011 3:03 PM
MENU > SYSTEM SETUP > LABEL AUX
On the SYSTEM SETUP screen, click the LABEL
AUX button to display the LABEL AUXILIARIES
screen. Click the FREEZE PROTECT button on the
LABEL AUXILIARIES menu to display the FREEZE
PROTECT menu.
Label Auxiliaries
Circuit
Circuit Name
Freeze
Aux 1
Cleaner
Yes
Aux 2
Low Speed
Yes
Aux 3
Spillover
Yes
Aux 4
Pool Light JL
No
Aux 5
Spa Light JL
No
Aux 6
Fountain
Yes
Aux 7
Blower
No
Aux 8
None
Yes
Freeze
Protect
Page
Down
Page
Up
Save
Water
Feature
Lights
Custom
General
Home
Menu OneTouch
Help
Back
Status
Thu June 23, 2011 3:03 PM
Select any piece of equipment in the DEVICE list and
change the temperature using the numeric keypad.
Once the temperature is set, click the ENTER button to
move to the next screen to assign freeze protection to a
selected piece of equip ment. If an incorrect value was
entered, click the CLEAR button on the keypad and try
again.
NOTE
The filter pump is always assigned to freeze
protection.
IMPORTANT
Information on Freeze Protection
Freeze protection is intended to protect equipment and
plumbing for short periods of freezing only. It does this
by activating the filtration pump and circulating the water
to prevent freeze inside equipment or plumbing. Freeze
protection does
not
guarantee that equipment will not be
damaged by extended periods of freezing temperatures
or power outages. In these conditions, the pool and spa
should be shut down completely (e.g. drained of water and
closed for the winter) until warmer weather exists.