11.8 To Re-label the Speed Preset
Each of the eight (8) speed presets has a label and each
of those labels can be changed from the default value.
MENU > SYSTEM SETUP > VSP SETUP
On the VSP SETUP screen, click SPEED LABEL of
the selected speed to display the VSP SPEED LABEL
screen.
On the GENERAL LABELS list, select the desired
device and click the SAVE button. Use PAGE UP /
PAGE DOWN to scroll though the list. If you want to
assign a new label, click the CUSTOM LABEL button.
See Section 4.9,
"Custom Label"
.
Home
Menu OneTouch
Help
Back
Status
Thu June 23, 2011 3:03 PM
VSP Speed Label
Next
11.9 Default Preset Speed Labels (RS
Combo and RS only)
When a pump is configured for FILTRATION, the
speed presets will be labeled as shown in the table
below. The presets can be relabeled.
DEFAULT Labels when Pump is configured for
FILTRATION
PRESET
#
POOL/SPA
COMBO
POOL/SPA
ONLY
SPEED
(RPM)
1
POOL
POOL
1725
2
SPA
SPEED2
2750
3
SPEED3 or
CLEANER
(if DIP S1-1 is on)
SPEED3 or
CLEANER
(if DIP S1-1 is on)
2750
4
SPEED4 or
SPILLOVER
(if DIP S1-3 is on)
SPEED4
2750
5
POOL HEAT
TEMP1
2250
6
SPA HEAT
TEMP2
2250
7
SOLAR HEAT
(if DIP S1-7 is off)
or HEATPUMP
(if DIP S1-7 is on)
or SPEED7
SOLAR HEAT
(if DIP S1-7 is on)
or HEATPUMP
(if DIP S1-7 is on)
or SPEED7
2750
8
INFLOOR
INFLOOR
2750
Preset 1:
The default label for preset #1 is POOL. This label is
tied to the pool filtration mode. Anytime the pool pump
is supposed to turn on, this preset is selected.
Preset 2:
On combo systems the default label for preset #2
is SPA. This label is tied to the spa filtration mode,
anytime the spa pump is supposed to turn on, this preset
is selected.
Preset 3:
On combo systems, if DIP switch S1-1 is ON, then the
default label for this preset is CLEANER. Anytime
the cleaner mode is turned on the pump will run at the
speed setting of this preset.
On a combo system, if DIP switch S1-1 is OFF, then the
default label for this preset is SPEED3.
Page 47
iAquaLink™ Web Connect Device for AquaLink
®
& PDA Control Systems
|
Owner's Manual
ENGLISH