Section 11. Variable Speed Pump
Setup
NOTE
This equipment may not be part of your system.
Please check with your installer.
A VARIABLE SPEED PUMP can be programmed to
run at any one (1) of its eight (8) speeds.
Power to the variable speed pump is switched on/off
by a relay, so to program the pump you need to set a
program time for the relay, and for any speeds that you
wish to run during the pump's on cycle.
In the example shown below the variable speed pump
is used for pool filtration, so it will be powered from
the FILTER PUMP relay. Therefore, to program the
variable speed pump you must first set a program time
for the FILTER PUMP relay, then you need to program
the desired pump speeds to turn on/off during the
FILTER PUMP cycle.
If you do not program any speeds to run during the
filtration cycle, then by default the variable speed pump
will run at the POOL speed setting during its filtration
cycle.
Example:
1. The total length of the fi ltration cycle is to be from
8am to 5pm. So program the FILTER PUMP to turn
on at 8am and to turn off at 5pm.
2. To run the variable speed pump at the SPEED3
setting from 8am to 1pm, select VSP SPD1 PGM,
then select SPEED3, program it to turn on at 8am
and off at 1pm.
3. To run the variable speed pump at the SPEED4
setting from 1pm to 5pm, select VSP SPD1 PGM,
then select SPEED4, program it to turn on at 1pm
and off at 5pm.
ON
OFF
DESCRIPTION
FILTER PUMP
8AM
5PM
Total duration of
filtration cycle
SPEED3
8AM
1PM
Pump runs at the
SPEED3 setting
SPEED4
1PM
5PM
Pump runs at the
SPEED4 setting
The VAR SPEED PUMP menu is used to select the
variable speed pump type (Jandy ePump™, Pentair
®
IntelliFlo
®
VF, Pentair IntelliFlo
®
VS, or Pentair
IntelliPro
®
VS) and to select the various pump settings.
To interface the IntelliPro
®
VS, select IntelliFlo
®
VS.
11.1 To Select the Pump/Model
MENU > SYSTEM SETUP > VSP SETUP
On the SYSTEM SETUP screen, click the VSP SETUP
button to display the VSP SETUP screen.
On the VSP SETUP screen, click the PUMP/MODEL
button to display the SELECT VSP screen.
The RESTORE SPD DEFAULTS button will set the
pump speeds, prime speeds and prime duration to their
factory default settings.
Home
Menu OneTouch
Help
Back
Status
Speed
Setup
Pump/Model
Application
Min
Max
Speed Duration
1
Jandy ePump
Filtration
400 RPM 3450 RPM 2500
:05
2 Intelliflo VS
Aux Pump
900 RPM 3000 RPM 2500
:05
3 Intelliflo VF
Not Installed
N/A N/A N/A N/A N/A
N/A
VSP Setup
Save
Restore Spd
Defaults
Thu June 23, 2011 3:03 PM
Priming
Priming
In the PUMP MODEL list, select the variable speed
pump type and click the SELECT button to save it.
Home
Menu OneTouch
Help
Back
Status
Select VSP
Select
Pump Model
ePump
Intelliflo VS
Intelliflo VF
Thu June 23, 2011 3:03 PM
Page 44