28 / 58
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
Manual of 11/06/2019 Rev. 1.8 “User Manual for 3000SP storage inverter”
Code
Country
Code
Country
Code
Country
00
Germany VDE AR-N4105
12
Poland
24
Cyprus
01
CEI 0-21 Internal
13
Germany BDEW
25
India
02
Australia
14
Germany VDE 0126
26
Philippines
03
Spain RD1699
15
Italy CEI 0-16
27
New Zealand
04
Turkey
16
UK-G83
28
America
05
Denmark
17
Greece - islands
29
Slovakia VSD
06
Greece - mainland
18
EU EN 50438
30
Slovakia SSE
07
Netherlands
19
EU EN 61727
31
Slovakia ZSD
08
Belgium
20
Korea
32
CEI 0-21 Areti
09
UK-G59
21
Sweden
33-49 Reserved
10
China
22
General Europe
11
France
23
CEI 0-21 External
3)
Battery type
Use the “Up” and “Down” keys to select the type of batteries connected to the system and press “OK” to
confirm. If DARFON (1), PYLON (2), SOLTARO (3), ALPHA.ESS (4) or General Lithium (5) batteries are
used, the setup of the 3000SP storage inverter will be completed; press “OK” to enter into the main
interface.
If other types of batteries are used and the DEFAULT (6) option has been set, additional battery
parameters must be entered, as shown below.
MENU
Battery
1.DARFON
DARFON 14S31P ESS
2.PYLON
PYLONTECH US2000 PLUS / US2000B
3.SOLTARO
SL-3KWH / SL-1KWH
4.ALPHA.ESS
M48112-P / SMILE-BAT
5.GENERAL LITHIUM
All batteries that comply with the CAN communication protocol (Tawaki
Maui and Weco ReSU 4K4)
6.DEFAULT
Lead-acid, gel and salty water batteries