20 / 58
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
Manual of 11/06/2019 Rev. 1.8 “User Manual for 3000SP storage inverter”
CT cable
Extension (network cable)
Connection to 3000SP
Red
orange / orange white /
brown / brown white
CT+
Black
green / green white /
blue / blue white
CT-
Figure 13 – Connecting the CT cables of the current sensors
3)
Unscrew the 4 screws (A) of the central cover with a star screwdriver (figure 13).
4)
Remove the waterproof cover (B), loosen the cable gland (C), and then remove the stopper (G).
5)
Route the CT cable through the cable gland to the right of the cover, connect the cable to the CT
terminal supplied, then insert the CT terminals into the corresponding ports (CTa for the exchange
sensor and CTpv for the production sensor).
6)
If using Pylontech batteries, the communication cable between the inverter and batteries is supplied
as an accessory inside the transparent bag in the inverter’s packaging. For Tawaki Maui and Weco
ReSu4kWh batteries, the cable is found inside the battery packaging.
Connect one terminal to the battery (BAT), and the other to the inverter (inverter).
Route the communication cable (inverter side) through the cable gland on the left side of the cover,
then insert the connector into the CAN port. Insert the battery-side connector (BAT end) into the
CAN port of the PYLONTECH, Tawaki Maui or Weco battery.