Function
Sets the arming slope or queries the current
setting.
Syntax
:SAMPle:ARMing:SLOPe {RISE|FALL}
:SAMPle:ARMing:SLOPe?
Example
:SAMPLE:ARMING:SLOPE RISE
:SAMPLE:ARMING:SLOPE?
→
:SAMPLE:ARMING:
SLOPE RISE
Description You can set or query the arming slope only
when the arming source is set to “
EXTernal
.”
: S A M P l e : A R M i n g : S O U R c e
: S A M P l e : A R M i n g : S O U R c e
: S A M P l e : A R M i n g : S O U R c e
: S A M P l e : A R M i n g : S O U R c e
: S A M P l e : A R M i n g : S O U R c e
Function
Sets the arming source or queries the current
setting.
Syntax
:SAMPle:ARMing:SOURce {AUTO|EXTernal}
:SAMPle:ARMing:SOURce?
Example
:SAMPLE:ARMING:SOURCE AUTO
:SAMPLE:ARMING:SOURCE?
→
:SAMPLE:ARMING:
SOURCE AUTO
: S A M P l e : G A T E ?
: S A M P l e : G A T E ?
: S A M P l e : G A T E ?
: S A M P l e : G A T E ?
: S A M P l e : G A T E ?
Function
Queries all settings related to the gate.
Syntax
:SAMPle:GATE?
Example
:SAMPLE:GATE?
→
:SAMPLE:GATE:MODE TIME;
TIME 1.000E+00
: S A M P l e : G A T E : M O D E
: S A M P l e : G A T E : M O D E
: S A M P l e : G A T E : M O D E
: S A M P l e : G A T E : M O D E
: S A M P l e : G A T E : M O D E
Function
Sets the gate mode or queries the current
setting.
Syntax
:SAMPle:GATE:MODE {EVENt|TIME}
:SAMPle:GATE:MODE?
Example
:SAMPLE:GATE:MODE EVENT
:SAMPLE:GATE:MODE?
→
:SAMPLE:GATE:
MODE EVENT
8.7.12 STARt Group
:STARt
: S A M P l e : G A T E : T I M E
: S A M P l e : G A T E : T I M E
: S A M P l e : G A T E : T I M E
: S A M P l e : G A T E : T I M E
: S A M P l e : G A T E : T I M E
Function
Sets the gate time or queries the current setting.
Syntax
:SAMPle:GATE:TIME <Time>
:SAMPle:GATE:TIME?
<Time>=0.1 ms to 1 s (in 0.1 ms steps)
Example
:SAMPLE:GATE:TIME 1MS
:SAMPLE:GATE:TIME?
→
:SAMPLE:GATE:
TIME 100.0E–03
Description You can set or query the gate time only when
the gate mode is set to “
TIME
.”
: S A M P l e : I N H i b i t ?
: S A M P l e : I N H i b i t ?
: S A M P l e : I N H i b i t ?
: S A M P l e : I N H i b i t ?
: S A M P l e : I N H i b i t ?
Function
Queries all settings related to inhibit.
Syntax
:SAMPle:INHibit?
Example
:SAMPLE:INHIBIT?
→
:SAMPLE:INHIBIT:STATE 1;
POLARITY POSITIVE
: S A M P l e : I N H i b i t : P O L a r i t y
: S A M P l e : I N H i b i t : P O L a r i t y
: S A M P l e : I N H i b i t : P O L a r i t y
: S A M P l e : I N H i b i t : P O L a r i t y
: S A M P l e : I N H i b i t : P O L a r i t y
Function
Sets the polarity of inhibit or queries the current
setting.
Syntax
:SAMPle:INHibit:POLarity {POSitive|
NETGative}
:SAMPle:INHibit?
Example
:SAMPLE:INHIBIT:POLARITY POSITIVE
:SAMPLE:INHIBIT:POLARITY?
→
:SAMPLE:
INHIBIT:POLARITY POSITIVE
Description You can set the polarity of inhibit only when
inhibit is turned “
ON (enabled)
” through the
“
:SAMPle:INHibit:STATe
” command.
: S A M P l e : I N H i b i t : S T A T e
: S A M P l e : I N H i b i t : S T A T e
: S A M P l e : I N H i b i t : S T A T e
: S A M P l e : I N H i b i t : S T A T e
: S A M P l e : I N H i b i t : S T A T e
Function
Turns ON/OFF inhibit or queries the current
setting.
Syntax
:SAMPle:INHibit:STATe {Boolean}
:SAMPle:INHibit?
Example
:SAMPLE:INHIBIT:STATE ON
:SAMPLE:INHIBIT:STATE?
→
:SAMPLE:INHIBIT:
STATE 1
8.7.11 SSTart Group
:SSTart
: S T A R t
: S T A R t
: S T A R t
: S T A R t
: S T A R t
Function
Starts the measurement (continuous
measurement).
Syntax
:STARt
Example
:START
8.7 Commands
: S S T a r t
: S S T a r t
: S S T a r t
: S S T a r t
: S S T a r t
Function
Executes the measurement once (single
measurement).
Syntax
:SSTart
Example
:SSTART