10-4
IM 704420-01E
10.6 Input/Output on the Rear Panel
Item
Specification
External arming input (EXT ARM IN)
Connector type
BNC
Input impedance
10 k
Ω
(typical value
*1
)
Input coupling
DC
Input level
TTL level
Allowable input voltage
–8 V to 13 V (DC+ACpeak)
range
Minimum pulse width
30 ns
Setup time
0 ns (possible even when the external arming and data signals are simultaneous.)
Inhibit input (INHIBIT IN)
Connector type
BNC
Input impedance
10 k
Ω
(typical value
*1
)
Input coupling
DC
Input level
TTL level
Allowable input voltage
–8 V to 13 V (DC+ACpeak)
range
Minimum pulse width
30 ns
Setup time
0 ns (possible even when the inhibit signal and data signal are simultaneous.)
Jitter DC output (DC OUT)
Connector type
BNC
Output impedance
50
Ω
(typical value
*1
)
Output coupling
DC
Output mode
Select jitter ratio output or determination output.
Output filter
Range of average coefficient: 1 to 10
Jitter ratio output range
Range: 0.00% to 100.00%, resolution: 0.01%
Determination output
Range of determination level: 0.00% to 100.00%, resolution: 0.01%
Correction coefficient
Correction coefficient
α
Range: 0.0001 to 9.9999, resolution: 0.0001
Correction coefficient
β
Range: -9.999 to 9.999%, resolution: 0.001%
Output level
*2
0 V to 5 VDC
Output level accuracy
*2, *3
±
10 mV
Monitor output of the RF signal (MONITOR OUT) and monitor output of the equalized RF signal (EQUALIZED RF).
Shares one connector.
Connector type
BNC
Output impedance
50
Ω
(typical value
*1
)
Output coupling
DC
Output level
*4
When the equalizer is OFF
•
Approximately 1/4 the RF signal (within
±
5 V) when the trigger mode is set to manual mode.
•
Approximately 4/5 the RF signal (within
±
5 V) when the trigger mode is set to auto or auto +
manual mode.
When the equalizer is ON
Approx.
±
0.5 V
Data signal output (SLICED RF OUT)
Connector type
BNC
Output impedance
50
Ω
(typical value
*1
)
Output coupling
DC
Output level
*2
TTL level
Clock signal output (CLOCK OUT)
Connector type
BNC
Output impedance
50
Ω
(typical value
*1
)
Output coupling
DC
Output level
*2
TTL level
*1 The typical value is a representative or standard value. It is not strictly guaranteed.
*2 When the monitor equipment receives the signal at high impedance (approx. 1 M
Ω
).
*3 Measured value under standard operating conditions as described in General Specifications after the warm-up time has
elapsed.
*4 When the monitor equipment receives the signal at 50
Ω
.