<6. Function block parameters and Methods>
6-35
IM 12A01A02-72E
3rd Edition : Oct. 01, 2015-00
Alarm / Status
TB .status
Conduct1-
TC1
Resist1-TC1
Conduct1-
TC2
Resist1-TC2
Temperature1
Concent1-
TC1
Concent1-
TC2
USP1
Empty
Conc. table error Fault
—
—
—
BAD-
maintenance
alarm, more
diagnosis
available
—
—
UNCERTAIN-
initial value
2nd comp.
matrix error
Fault BAD-
maintenance
alarm, more
diagnosis
available
BAD-
maintenance
alarm, more
diagnosis
available
—
BAD-
maintenance
alarm, more
diagnosis
available
BAD-
maintenance
alarm, more
diagnosis
available
—
1st. comp.
matrix error
Fault BAD-
maintenance
alarm, more
diagnosis
available
BAD-
maintenance
alarm, more
diagnosis
available
—
BAD-
maintenance
alarm, more
diagnosis
available
BAD-
maintenance
alarm, more
diagnosis
available
—
Checksum error Fault BAD-maintenance alarm, more diagnosis available
EEPROM error Fault BAD-maintenance alarm, more diagnosis available
Sens. mod. not
work
Fault BAD-maintenance alarm, more diagnosis available
Logbook
(almost) full
Warning
GOOD-maintenance required
Calibration Due
Warning
GOOD-
maintenance
required
GOOD-
maintenance
required
—
GOOD-
maintenance
required
GOOD-
maintenance
required
GOOD-
maintenance
required
Conductivity too
high
Warning
UNCERTAIN-
process
related, no
maintenance
UNCERTAIN-
process
related, no
maintenance
—
UNCERTAIN-
process
related, no
maintenance
UNCERTAIN-
process
related, no
maintenance
UNCERTAIN-
process
related, no
maintenance
Conductivity too
low
Warning
UNCERTAIN-
process
related, no
maintenance
UNCERTAIN-
process
related, no
maintenance
—
UNCERTAIN-
process
related, no
maintenance
UNCERTAIN-
process
related, no
maintenance
UNCERTAIN-
process
related, no
maintenance
Temperature too
high
Warning
UNCERTAIN-process related, no maintenance
Temperature too
low
Warning
UNCERTAIN-process related, no maintenance
1st temp. comp.
error
Warning
UNCERTAIN-
process
related, no
maintenance
—
—
—
UNCERTAIN-
process
related, no
maintenance
—
2nd temp. comp.
error
Warning
—
UNCERTAIN-
process
related, no
maintenance
—
UNCERTAIN-
process
related, no
maintenance
—
—
Polarization
detected
Warning
UNCERTAIN-
maintenance
demanded
UNCERTAIN-
maintenance
demanded
—
UNCERTAIN-
maintenance
demanded
UNCERTAIN-
maintenance
demanded
UNCERTAIN-
maintenance
demanded
USP limit
exceeded
Warning
UNCERTAIN-
process
related, no
maintenance
UNCERTAIN-
process
related, no
maintenance
—
UNCERTAIN-
process
related, no
maintenance
UNCERTAIN-
process
related, no
maintenance
UNCERTAIN-
process
related, no
maintenance
USP margin
exceeded
Warning
UNCERTAIN-
process
related, no
maintenance
UNCERTAIN-
process
related, no
maintenance
—
UNCERTAIN-
process
related, no
maintenance
UNCERTAIN-
process
related, no
maintenance
UNCERTAIN-
process
related, no
maintenance
Conc. table error
Warning
—
—
—
BAD-
maintenance
alarm, more
diagnosis
available
—
—
2nd. comp.
matrix error
Warning
BAD-
maintenance
alarm, more
diagnosis
available
BAD-
maintenance
alarm, more
diagnosis
available
—
BAD-
maintenance
alarm, more
diagnosis
available
BAD-
maintenance
alarm, more
diagnosis
available
—