Administrator’s Guide for SIP-T2 Series/T19(P) E2/T4 Series/T5 Series IP Phones
678
Parameters
Permitted Values
Default
static.network.port.max_rtpport
Integer from
1024 to 65535
12780
Description:
Configures the maximum local RTP port.
Note
: The value of the maximum local RTP port cannot be less than that of the minimum
local RTP port (configured by the parameter “static.network.port.min_rtpport”). If you
change this parameter, the IP phone will reboot to make the change take effect.
Web User Interface:
Network->Advanced->Local RTP Port->Max RTP Port (1024~65535)
Phone User Interface:
None
To configure the minimum and maximum RTP port via web user interface:
1.
Click on
Network
->
Advanced
.
2.
In the
Local RTP Port
block, enter the max and min RTP port in the
Max RTP Port
(1024~65535)
and
Min RTP Port (1024~65535)
field respectively.
3.
Click
Confirm
to accept the change.
A dialog box pops up to prompt that the settings will take effect after a reboot.
4.
Click
OK
to reboot the phone.
Содержание SIP-T19 E2 T4 Series
Страница 1: ...63 ...
Страница 532: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series T5 Series IP Phones 510 ...
Страница 734: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series T5 Series IP Phones 712 ...
Страница 814: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series T5 Series IP Phones 792 ...
Страница 850: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series T5 Series IP Phones 828 ...
Страница 887: ...Troubleshooting 865 The phone begins rebooting Any reboot of the phone may take a few minutes ...