Administrator’s Guide for SIP-T2 Series/T19(P) E2/T4 Series/T5 Series IP Phones
134
When a call is muted.
When a call is placed on hold or is held.
When the IP phone is busy.
When the IP phone misses a call.
Procedure
Power indicator LED can be configured using the following methods.
Central
Provisioning
(Configuration
File)
<y0000000000
xx>.cfg
Configure the power indicator LED.
Parameters:
phone_setting.common_power_led_enable
phone_setting.ring_power_led_flash_enable
phone_setting.mail_power_led_flash_enable
phone_setting.mute_power_led_flash_enable
phone_setting.hold_and_held_power_led_flash_enable
phone_setting.talk_and_dial_power_led_enable
phone_setting.missed_call_power_led_flash.enable
Web User Interface
Configure the power indicator LED.
Navigate to
:
http://<phoneIPAddress>/servlet?p=features-powerl
ed&q=load
Details of Configuration Parameters:
Parameters
Permitted
Values
Default
phone_setting.common_power_led_enable
0 or 1
0
Description:
Enables or disables the power indicator LED to be turned on.
For
SIP-T54S/T52S/T48G/T48S/T46G/T46S/T42G/T42S/T41P/T41S/T40P/T40G/T29G/T27
P/T27G/T23P/T23G/T21(P) E2 IP phones
:
0
-Disabled (power indicator LED is off)
1
-Enabled (power indicator LED is solid red)
For SIP-T19(P) E2 IP phones
:
0
-Disabled (power indicator LED is off)
1
-Enabled (power indicator LED is solid yellow)
Web User Interface:
Содержание SIP-T19 E2 T4 Series
Страница 1: ...63 ...
Страница 532: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series T5 Series IP Phones 510 ...
Страница 734: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series T5 Series IP Phones 712 ...
Страница 814: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series T5 Series IP Phones 792 ...
Страница 850: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series T5 Series IP Phones 828 ...
Страница 887: ...Troubleshooting 865 The phone begins rebooting Any reboot of the phone may take a few minutes ...