B.3 Parameter Table
B.3 Parameter Table
◆
A: Initialization Parameters
The A parameter group creates the operating environment for the drive. This includes the parameter Access Level, Motor
Control Method, Password, User Parameters and more.
No.
Name
Description
Range
Def.
Control
Mode
Addr.
Hex
Pg.
V/f OL
V
P
M
A1: Initialization Parameters
Use A1 parameters to configure the basic environment for drive operation.
A1-00
Language Selection
0: English
1: Japanese
2: German
3: French
4: Italian
5: Spanish
6: Portuguese
7: Chinese
0 to 7
0
A A A
100
A1-01
<15> Parameter can be changed during run.
<18> Parameter setting value is not reset to the default value during drive initialization, A1-03 = 1110, 2220, 3330.
Access Level Selection
Selects which parameters are accessible via the digital operator.
0: Operation only
1: User Parameters (access to a set of parameters selected by the
user)
2: Advanced Access Level
0 to 2
2
A A A
101
A1-02
Control Method
Selection
Selects the Control Method of the drive.
Auto-Tuning must be performed when selecting A1-02 = 2, 5.
0: V/f Control without PG
2: Open Loop Vector (OLV)
5: PM Open Loop Vector (PM)
0, 2, 5
0
S S S
102
A1-03
Initialize Parameters
Resets all parameters to factory default settings. (Initializes the
drive then returns A1-03 to 0)
0: No Initialize
1110: User Initialize
(First set user parameter values must be stored using parameter
o2-03)
2220: 2-Wire Initialization
3330: 3-Wire Initialization
5550: oPE04 Error Reset
0 to 5550
0
A A A
103
The following parameters are not reset when
the performing initialization: A1-00, A1-02,
A1-07, E1-03, F6-08, L8-35, o2-04, and o2-
09.
A1-04
Password
When the value set into A1-04 does not match the value set into
A1-05, parameters A1-01 through A1-03, and A2-01 through
A2-32 cannot be changed.
0 to 9999
0
A A A
104
A1-05
Password Setting
0 to 9999
0
A A A
105
This parameter is hidden from view.
To access A1-05, first display A1-04.
Then press the STOP key while
holding down the up arrow key.
Parameter A1-05 will appear.
–
A2: User Parameters
Use A2 parameters to program the drive.
A2-01 to
A2-32
User Parameters 1 to
32
Parameters that were recently edited are listed here. The user can
also select parameters to appear here for quick access.
Parameters will be stored here for quick access when A1-01 = 1.
A1-00 to
o2-08
–
A A A
106 to
125
A2-33
User Parameter
Automatic Selection
0: Parameters A2-01 through A2-32 are reserved for the user to
create a list of User Parameters.
1: Save history of recently viewed parameters. Recently edited
parameters will be saved to A2-17 through A2-32 for quick
access.
0,1
1
A A A
126
Содержание T1000V
Страница 10: ...10 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 30: ...1 4 Component Names 30 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 44: ...2 2 Mechanical Installation 44 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 100: ...4 10 Test Run Checklist 100 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 232: ...5 12 U Monitor Parameters 232 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 280: ...6 9 Troubleshooting without Fault Display 280 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 294: ...7 5 Drive Replacement 294 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 306: ...8 5 Communication Options 306 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 316: ...A 6 Drive Derating Data 316 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 422: ...D 4 Safe Disable Input Precautions 422 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...