5.11 S: Functions for Textile Applications
220
YASKAWA ELECTRIC
SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
■
S1-01: Disturb Function Selection
Enables or disables the Disturb function. If enabled, the Disturb waveform is generated when the frequency reference
and output frequency match (referred to as "speed agree").
0: Disabled
1: Enabled
2: Enabled, Outputs the Disturb Waveform During Accel/Decel
■
S1-02: Disturb Function Amplitude
Sets the amplitude of the Disturb waveform as a percentage of the frequency reference.
■
S1-03: Disturb Step
Sets the step applied at the end of disturb acceleration or deceleration as a percentage of the Disturb amplitude in S1-02.
■
S1-04: Disturb Deceleration Time
Sets the deceleration time for the Disturb function.
■
S1-05: Disturb Acceleration Time
Sets the acceleration time for the Disturb function.
◆
S2: Frequency Reference Gain Settings
Independent of the frequency reference source selected, this function applies a gain to the frequency reference value.
A gain change ramp can be used in order to avoid speed steps when the gain value in S2-02 is modified.
■
S2-01: Frequency Reference Gain
Determines how much to reduce or amplify the frequency reference. Note that the frequency reference cannot exceed the
upper limit set to d2-01, regardless of how high S2-01 is set.
■
S2-02: Frequency Reference Gain Change Ramp
Determines the time the drive uses to change the frequency reference gain. Set as the time to change the gain from 0 to 100%.
No.
Name
Setting Range
Default
S1-01
Disturb Function Selection
0 to 2
0
No.
Name
Setting Range
Default
S1-02
Disturb Function Amplitude
0.00 to 20.00%
0.00%
No.
Name
Setting Range
Default
S1-03
Disturb Step
0 to 50%
0%
No.
Name
Setting Range
Default
S1-04
Disturb Deceleration Time
0. to 120.0 s
0.0 s
No.
Name
Setting Range
Default
S1-05
Disturb Acceleration Time
0.0 to 120.0 s
0.0 s
No.
Name
Setting Range
Default
S2-01
Frequency Reference Gain
0.00 to 1000.00%
100.00%
No.
Name
Setting Range
Default
S2-02
Frequency Reference Gain Change Ramp
0.0 to 600.0 s
0.0 s
Содержание T1000V
Страница 10: ...10 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 30: ...1 4 Component Names 30 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 44: ...2 2 Mechanical Installation 44 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 100: ...4 10 Test Run Checklist 100 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 232: ...5 12 U Monitor Parameters 232 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 280: ...6 9 Troubleshooting without Fault Display 280 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 294: ...7 5 Drive Replacement 294 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 306: ...8 5 Communication Options 306 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 316: ...A 6 Drive Derating Data 316 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...
Страница 422: ...D 4 Safe Disable Input Precautions 422 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual...