No.
(Addr.
Hex)
Name
LCD Display
Description
Analog
Output Level
Unit
U1-12
(004B) Drive Status
Int Ctl Sts 1
Verifies the drive operation status.
U1 - 12=
00000000
During run
During zero-speed
During REV
During fault reset
signal input
During speed agree
Drive ready
During alarm
detection
During fault detection
1
1
1
1
1
1
1
1
No signal output
available
–
U1-13
(004E)
Terminal A1 Input
Level
Term A1 Level
Displays the signal level to analog input terminal A1.
10 V: 100%
0.1%
U1-14
(004F)
Terminal A2 Input
Level
Term A2 Level
Displays the signal level to analog input terminal A2.
10 V: 100%
0.1%
U1-15
(0050)
Terminal A3 Input
Level
Term A3 Level
Displays the signal level to analog input terminal A3.
10 V: 100%
0.1%
U1-16
(0053)
Output Frequency after
Soft Starter
SFS Output
Displays output frequency with ramp time and S-curves. Units
determined by o1-03.
10 V: Max
frequency
0.01 Hz
U1-18
(0061)
oPE Fault Parameter
OPE Error Code
Displays the parameter number that caused the oPE02 operation
error.
No signal output
available
–
U1-19
(0066)
MEMOBUS/Modbus
Error Code
Transmit Err
Displays the contents of a MEMOBUS/Modbus error.
U1 - 19=
00000000
CRC Error
Data Length Error
Not Used
Parity Error
Overrun Error
Framing Error
Timed Out
Not Used
1
1
0
1
1
1
1
0
No signal output
available
–
U1-24
(007D) Input Pulse Monitor
Term RP Inp Freq
Displays the frequency to pulse train input terminal RP.
Determined by
H6-02
1 Hz
U1-25
(004D)
Software Number
(Flash)
CPU 1 SW Number
FLASH ID
No signal output
available
–
U1-26
(005B) Software No. (ROM)
CPU 2 SW Number
ROM ID
No signal output
available
–
U1-75
(0851)
Time-Hour/Minute
Time Hr Min HHMM Displays the current time (Hours and Minutes).
No signal output
available
–
U1-76
(0852)
Date – Year
Date Year
Displays the current year.
No signal output
available
–
U1-77
(0853)
Date – Month/Day
Date Mo Day MMDD Displays the current date (Month and Date).
No signal output
available
–
U1-78
(0854)
Date – Week Day
Date Week
Displays the current day of the week.
0: Sunday
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
No signal output
available
–
U1-80
(0B9B)
Geothermal
Temperature Input
Geothermal Temp
Displays the geothermal temperature input after the gain and
bias have been applied. This temperature is used by the
Geothermal Function to determine the proper frequency at
which to run the drive.
This monitor is internally limited to -999.9
°
F to +999.9
°
F.
No signal output
available
0.1
°
F
B.15 U: Monitors
YASKAWA
TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
327
B
Parameter List
Содержание iQpump1000
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive iQpump1000 Quick Start Guide...
Страница 12: ...This Page Intentionally Blank 12 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive iQpump1000 Quick Start Guide...
Страница 353: ...This Page Intentionally Blank YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive iQpump1000 Quick Start Guide 353...
Страница 355: ......