Three-Phase 600 V Class Drive Models 5A0041 to 5A0099
Table A.8 Power Ratings Continued (Three-Phase 600 V Class)
Item
Specification
Drive Models
5A0041
5A0052
5A0062
5A0077
5A0099
Maximum Applicable Motor Capacity (HP)
ND Rating
40
50
60
75
100
Input
Input Current (A)
ND Rating
44
54
66
80
108
Rated Voltage
Rated Frequency
Three-phase 500 to 600 Vac 50/60 Hz
Allowable Voltage Fluctuation
-10 (-15) to +10%
Allowable Frequency Fluctuation
±5%
Input Power (kVA)
ND Rating
50
62
75
91
123
Output
Rated Output Capacity (kVA)
ND Rating
41
52
62
77
99
Rated Output Current (A)
ND Rating
41
52
62
77
99
Overload Tolerance
ND Rating: 120% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
User-adjustable between 1 and 10 kHz
User-
adjustable
between 1 and
Maximum Output Voltage (V)
Three-phase 500 to 600 V (proportional to input voltage)
Maximum Output Frequency (Hz)
400 Hz (user-set)
connections, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 575 V.
<4> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings
raise the carrier frequency and require current derating.
A.1 Power Ratings
YASKAWA
TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
241
A
Specifications
Содержание iQpump1000
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive iQpump1000 Quick Start Guide...
Страница 12: ...This Page Intentionally Blank 12 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive iQpump1000 Quick Start Guide...
Страница 353: ...This Page Intentionally Blank YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive iQpump1000 Quick Start Guide 353...
Страница 355: ......