No.
(Addr.
Hex)
Name
LCD Display
Description
Values
Page
E2-04
(0311)
Number of Motor Poles Number of Poles
Sets the number of motor poles. Automatically set during
Auto-Tuning.
Default: 2
Min.: 2
Max.: 48
–
E2-05
(0312)
Motor Line-to-Line
Resistance
Term Resistance
Sets the phase-to-phase motor resistance. Automatically set
during Auto-Tuning.
Min.: 0.000 Ω
Max.: 65.000 Ω
–
E2-06
(0313)
Motor Leakage
Inductance
Leak Inductance
Sets the voltage drop due to motor leakage inductance as a
percentage of motor rated voltage. Automatically set during
Auto-Tuning.
Min.: 0.0%
Max.: 40.0%
–
E2-07
(0314)
Motor Iron-Core
Saturation Coefficient 1 Saturation Comp1
OLV
OLV
OLV
OLV
Sets the motor iron saturation coefficient at 50% of magnetic
flux. Automatically set during Auto-Tuning.
Default: 0.50
Min.: E2-07
Max.: 0.50
–
E2-08
(0315)
Motor Iron-Core
Saturation Coefficient 2 Saturation Comp2
OLV
OLV
OLV
OLV
Sets the motor iron saturation coefficient at 75% of magnetic
flux. Automatically set during Auto-Tuning.
Default: 0.75
Min.: E2-07
Max.: 0.75
–
E2-09
(0316)
Motor Mechanical Loss Mechanical Loss
OLV
OLV
OLV
OLV
Sets the motor mechanical loss as a percentage of motor rated
power (kW).
Default: 0.0%
Min.: 0.0
Max.: 10.0
–
E2-10
(0317)
Motor Iron Loss for
Torque Compensation
Motor Iron Loss
V/f
V/f
Sets the motor iron loss.
Min.: 0 W
Max.: 65535 W
–
E2-11
(0318)
Motor Rated Power
Mtr Rated Power
Sets the motor rated power in kilowatts (1 HP = 0.746 kW).
Automatically set during Auto-Tuning.
Min.: 0.00 kW
Max.: 650.00
kW
–
<1> Default setting is dependent on parameter o2-04, Drive Model Selection.
<2> The number of decimal places in the parameter value depends on the drive model. This value has two decimal places (0.01 A) if the drive is set for
B.5 E: Motor Parameters
YASKAWA
TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
271
B