![Yamato Just NAVI J-101W Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/yamato/just-navi-j-101w/just-navi-j-101w_operation-manual_905383029.webp)
Chapter 6 How to use the Multi-functions
28
6-2. Fixed
weighing
function
(Note) The fixed weighing function cannot be used for transactions or certifications stipulated by the
Measurement Act.
* When "NOT LEGAL" is displayed in the lower left of the panel, you
cannot use the results for transactions or certifications stipulated by the
Measurement Act.
Fixed weighing function
Application
Fixed weight packing work
Weighing method
The Main-display shows the insufficient weight as a minus value, and it shows 0
g when the measured value has exactly reached the allowable weight.
Advantage
The operator can quickly tell how many grams are still needed to reach the target
weight, and so anyone can conduct the work easily.
Setting values
• Target value
• Tolerance (weight in grams which may be deviated from the target value)
• Preset tare (when the Preset tare function is used)
Indication on Main-
display
Insufficient/excessive weight to the target
Indication on Sub-
display
Target value
Max number of
program entries
99 programs
For the Fixed weighing function, you need to make two settings: the target value
and its tolerance
.
Underweight Allowable
weight Overweight
Lamp goes out
Blue lamp comes on
Lamp goes out
100 g (target value)
(100+) 9 g (tolerance)
* You can change the condition of turning on the blue lamp with user parameters.
* The above is a case when the weighing capacity is 3000 g.
The insufficient weight needed to reach the
target value is shown as a minus value.
Target weight
Allowable weight lamp comes on.