Chapter 4 User parameters
15
Chapter 4 User parameters
4-1.
About user parameters
Just NAVI™ allows you to change the settings to best fit for your needs and applications. Change the settings
as needed, referring to the user parameter table below.
4-2.
User parameter table
No.
Item
Option Function (Underlined options are factory defaults.)
#01 Multi-function
0: Disabled
1: Fixed weighing function
2: Checkweighing function
3: Ranking function
4: Counting function
5: Ranking combination function
#03 Evaluation lamp lighting timing
selection
(Parameter for Multi-function)
0: No light
1: Steady light upon underweight
2: Steady light upon allowable weight
3: Steady light upon overweight
4: Steady light upon underweight and blinking upon
overweight
#04 Evaluation
timing
0: Evaluate even when unstable
(Parameter for Multi-function)
1: Evaluate only when stable
#05 Automatic power OFF time
0: Disabled
1: OFF in 5 minutes
2: OFF in 10 minutes
3: OFF in 15 minutes
4: OFF in 30 minutes
5: OFF in 60 minutes
#07 Blinking of indicated value based
on the evaluation
(Parameter for Multi-function)
0: No blinking
1: Blinking upon underweight
2: Blinking upon allowable weight
3: Blinking upon overweight
4: Blinking upon underweight or overweight
5: User the parameter #03: (Evaluation lamp lighting
timing) for blinking
For the evaluation lamp and the
ranking of the rank combination
function, you can change the
condition whether an evaluation
can be made when the measured
value is stable or unstable.
You can select a function of the
multi-function described in Section
5-4 and Chapter 6.
When the multi-function is used,
you can set the timing at which the
evaluation lamp is turned on.
You can change the automatic
power OFF time. If there is no
change in weight for the period
specified here, the instrument
automatically powers off.
When the multi-function is used,
you can specify a condition under
which the value on the Main-display
should blink: when the measured
value is underweight, allowable
weight, or overweight.