6 - 19
–
+
ELEC
Ê
The thermo switch circuit is open.
Ë
The thermo switch circuit is closed.
Test step Water temperature Continuity
1
TT-R90:
Less than 23
±
3 °C
(73.4
±
5.4 °F)
TT-R90E:
Less than 16
±
3 °C
(60.8
±
5.4 °F)
YES
2
TT-R90:
More than 23
±
3 °C
(73.4
±
5.4 °F)
TT-R90E:
More than 16
±
3 °C
(60.8
±
5.4 °F)
NO
3
TT-R90:
More than 12
±
4 °C
(53.6
±
7.2 °F)
TT-R90E:
More than 11
±
3 °C
(51.8
±
5.4 °F)
NO
4
TT-R90:
Less than 12
±
4 °C
(53.6
±
7.2 °F)
TT-R90E:
Less than 11
±
3 °C
(51.8
±
5.4 °F)
YES
Test steps 1 & 2: Heating phase
Test steps 3 & 4: Cooling phase
WARNING
• Handle the thermo switch with special
care.
• Never subject the thermo switch to
strong shocks. If the thermo switch is
dropped, replace it.
• Check the thermo switch operation.
È
É
CARBURETOR HEATING SYSTEM