2. Troubleshooting
2.3
Troubleshooting checkpoints
1. Installation and power supply
1
2
3
Symptom
Controller won't turn on
even with power supplied.
Controller turns on but no
MPB display.
Controller turns on but
“ERR” LED on front panel
lights up.
Possible cause
• Power not supplied.
• Problem in controller
internal power.
• MPB not connected.
• Wrong MPB connection.
• MPB malfunctioning.
• Problem in controller
internal power supply.
• Now in emergency stop.
• Error of error group No.
17 occurred.
• Error of error group No.
21, 22 occurred.
Corrective action
• Connect power input terminal
correctly.
• Supply rated power supply
voltage.
• Replace the controller.
• Plug in MPB connector
correctly.
• Replace the MPB.
• Replace the controller.
• Release MPB emergency stop
switch.
• Insert MPB connector.
• Connect the emergency stop
terminal of SAFETY
connector.
• Check the axis from the error
information.
• Check the cause from the
error information.
• Eliminate the cause of the
error.
• Check the cause from the
error information.
• Eliminate the cause of the
error.
Check items
• Check power input terminal
connection (L/N/GND).
• Check power input terminal
voltage (L/N/GND).
• Check if “PWR” LED on front
panel is lit.
• Check MPB connector.
• Check how MPB connector is
inserted.
• Replace MPB and check
operation.
• Connect the MPB and check
the error history.
• Check DI00 on MPB screen.
• Connect the MPB and check
the error history.
• Connect the MPB and check
the error history.
Содержание RCX142
Страница 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E92 Ver 1 09 RCX142 ...
Страница 2: ......
Страница 18: ...MEMO ...
Страница 24: ...1 6 MEMO ...
Страница 26: ...MEMO ...
Страница 36: ...MEMO ...
Страница 300: ...4 238 MEMO ...
Страница 302: ...MEMO ...
Страница 336: ...MEMO ...
Страница 360: ...6 24 MEMO ...
Страница 362: ...MEMO ...
Страница 374: ...MEMO ...
Страница 384: ...8 10 MEMO ...
Страница 386: ...MEMO ...
Страница 394: ...MEMO ...