4-
76
Operation
4
11. “MANUAL” mode
If robot movement beyond the +/- soft limits is attempted with the Jog keys, the error
message “2.1: Over soft limit” appears and the robot does not move. Likewise, if
robot movement beyond the shift coordinate range is attempted, the error message
“2.11: Exceeded shift coord. range” appears and the robot does not move.
If the current position is outside the soft limits, the error message “2.1: Over soft
limit” also appears and the robot does not move.
2. When return-to-origin is not complete
(1) When the current position is displayed in “pulse” units:
Robot movement with the Jog keys is possible the same as when return-to-origin
is complete. However, the message “0.1: Origin incomplete” appears when a Jog
key is pressed.
(2) When the current position is displayed in “mm” units:
The robot does not move with the Jog keys. The current position display
switches automatically to “pulse” units and the error message “0.1: Origin
incomplete” appears. Perform absolute reset at this point.
c
CAUTION
If return-to-origin is incomplete, the
soft limits do not work correctly.
n
NOTE
If return-to-origin is incomplete, the
current position always appears as
"pulse" units when the controller is
turned on.
Содержание RCX142
Страница 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E92 Ver 1 09 RCX142 ...
Страница 2: ......
Страница 18: ...MEMO ...
Страница 24: ...1 6 MEMO ...
Страница 26: ...MEMO ...
Страница 36: ...MEMO ...
Страница 300: ...4 238 MEMO ...
Страница 302: ...MEMO ...
Страница 336: ...MEMO ...
Страница 360: ...6 24 MEMO ...
Страница 362: ...MEMO ...
Страница 374: ...MEMO ...
Страница 384: ...8 10 MEMO ...
Страница 386: ...MEMO ...
Страница 394: ...MEMO ...