10-
3
10
T
roubleshooting
1. Error Messages
[ 0] Warnings and messages
0.0
: Undefined error
Code
: &H0000
Meaning/Cause
: Undefined system error.
Action
: Contact our company.
0.1
: Origin incomplete
* If the cause of the Origin incomplete error can be pinpointed, an error code will be
attached in parentheses at the end.
Code
: &H0001
Meaning/Cause
: a. Return-to-origin is incomplete because absolute reset has not
been performed. So you …
• cannot execute programs and commands.
• cannot perform point teaching.
• cannot perform manual Cartesian movement (mm units).
b. Absolute battery was removed from controller or robot posi-
tion data becomes undefined due to battery voltage drop.
c. Robot I/O cable was removed or disconnected.
d. Absolute reset was interrupted.
e. System generation was changed or parameters initialized. Or
parameters for specifying the origin position such as for the
return-to-origin direction or axis polarity were changed.
(Equivalent to writing ALL or PRM file on controller.)
Action
: Perform absolute reset and complete return-to-origin.
0.2
: Running
Code
: &H0002
Meaning/Cause
: Program or command is running.
Action
: ---
0.3
: Program terminated by “HALT”
Code
: &H0003
Meaning/Cause
: Program execution was terminated by a HALT command.
Action
: ---
0.4
: Compiling
Code
: &H0004
Meaning/Cause
: Robot language compiling (making an object program) is in
progress.
Action
: ---
0.5
: Busy
Code
: &H0005
Meaning/Cause
: Data is being saved on a memory card or internal ROM.
Action
: ---
Содержание RCX142
Страница 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E92 Ver 1 09 RCX142 ...
Страница 2: ......
Страница 18: ...MEMO ...
Страница 24: ...1 6 MEMO ...
Страница 26: ...MEMO ...
Страница 36: ...MEMO ...
Страница 300: ...4 238 MEMO ...
Страница 302: ...MEMO ...
Страница 336: ...MEMO ...
Страница 360: ...6 24 MEMO ...
Страница 362: ...MEMO ...
Страница 374: ...MEMO ...
Страница 384: ...8 10 MEMO ...
Страница 386: ...MEMO ...
Страница 394: ...MEMO ...