4-
210
Operation
4
12. “SYSTEM” mode
2) Enter the stroke in "mm" units and press
. Up to 2 decimal places are allowed.
Refer to the drawing below to determine the stroke.
Fig. 4-12-88 Stroke setting
Origin position
Origin position
Point where one carrier is closest to the other
Stroke
2. Carrier 1 setting
3. Carrier 2 setting
[Procedure]
1) Select "2. Carrier 1" or "3. Carrier 2" and press
F 1
(EDIT).
Fig. 4-12-89 Double-carrier parameter setting (3)
SYSTEM
>OPTION>W.CARRIER>EDIT
V8.58
1.Stroke[mm]
650.00
2.
Carrier1
M1
3.Carrier2
M2
4.Control mode
OFF
M1
M2
M3
M4
M5
2) Select the double-carrier axis with the function key.
n
NOTE
Each function key display differs
depending on how the axis is set.