3-
6
Installation
3
4. Connecting to the power
Connect ring-tongue terminals to the power cable and screw them to the terminal block on the front
panel of the controller as shown below.
4.1
AC200 to 230V single-phase specifications
Remarks
Wiring thickness
2.0mm
2
or more
Tightening torque
1.4Nm
Ground side
Symbol
L
N
Wiring
A C I N
A C I N
Earth
Hot
Neutral (cold)
Grounding resistance 100 ohms or less
Fig. 3-4-1 Terminal block (AC 200 to 230V specifications)
L
N
Hot
Neutral
Earth
4.2
Power capacity
The required power capacity depends on the robot model and the number of axes to be
controlled. Prepare a suitable power supply while referring to the tables below.
Controller: RCX142
(1) When connected to SCARA robot
Standard type
YK180X, 220X
YK250XH, 350XH, 400XH
YK550X, 500XG, 600XG
YK600XGH, 700XG, 800XG,
900XG, 1000XG, 1200X
Clean type
YK250XCH, 350XCH, 400XCH
YK500XC, 600XC
YK700XC, 800XC, 1000XC
Dust-proof & drip-proof type
YK250XP, 350XP, 400XP
YK500XP, 600XP
YK700XP, 800XP, 1000XP
Ceiling-hanging/inverse type
YK300XS, 400XS
YK500XS, 600XS
YK700XS, 800XS, 1000XS
Power
capacity
(VA)
500
1000
1500
1700
2000
2500
Robot model
(2) When connected to 2 axes (Cartesian robot or multi-axis robot)
Axis current sensor value
X-axis
05
10
20
10
20
20
Y-axis
05
05
05
10
10
20
Power capacity (VA)
600
800
1100
1000
1300
1700
c
CAUTION
Before connecting the power cable, be
sure to check that the power supply
voltage matches the power
specifications of your controller.
c
CAUTION
The power supply voltage for the
robot controller must always be
regulated within
±
10%. If the voltage
drops, the robot controller may issue
an abnormal voltage alarm causing
the robot to trigger emergency stop.
In contrast, operation at a voltage
higher than specified may damage the
robot controller or trigger emergency
stop due to detecting an excessive
motor power supply voltage.
w
WARNING
• To prevent electrical shocks
or faulty operation caused by
noise, the earth terminal
(protective conductor) must
be grounded properly.
• To prevent electrical shocks,
never touch the AC IN
terminals when power is
supplied to the robot
controller.
Содержание RCX142
Страница 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E92 Ver 1 09 RCX142 ...
Страница 2: ......
Страница 18: ...MEMO ...
Страница 24: ...1 6 MEMO ...
Страница 26: ...MEMO ...
Страница 36: ...MEMO ...
Страница 300: ...4 238 MEMO ...
Страница 302: ...MEMO ...
Страница 336: ...MEMO ...
Страница 360: ...6 24 MEMO ...
Страница 362: ...MEMO ...
Страница 374: ...MEMO ...
Страница 384: ...8 10 MEMO ...
Страница 386: ...MEMO ...
Страница 394: ...MEMO ...