4-
70
Operation
4
10. “PROGRAM” mode
10.7 Resetting an error in the selected program
If an error “9.1 Program destroyed” occurs in the selected program data, this function
resets the error and allows you to continue editing.
[Procedure]
1) Press the
F 13
(ERR. RST) key in “PROGRAM” mode.
A confirmation message appears on the guideline.
Fig. 4-10-33
PROGRAM
<TEST2 >
1
’***** TEST2 PROGRAM *****
2 GOSUB *SUBPROG
3 DO2(0)=-^23-OFW
4 WAIT DI3(4,3,2)=3
5 MOVE P,P0 ’ORIGIN
Error reset OK?
———————————————————————————————————————————
1
2
3
YES
NO
>ERROR RESET
2) Press the
F 4
(YES) key to reset the error.
The program can be edited after resetting the error.
Press the
F 5
(NO) key if you want to cancel the error reset.
c
CAUTION
This function resets an error, but does
not restore the program data. A
problem is probably occurring in the
program, so check and correct the
program in “PROGRAM>EDIT”
mode.
n
NOTE
• This function is enabled for each
program.
• This reset function does not work
if an error “9.3 Memory
destroyed” occurs. In this case,
initialize the memory.