BRKT
Bracket unit
9-37
Removing the PTT unit
When removing the PTT unit with the
power unit installed, make sure to sus-
pend the outboard motor.
1.
Fully tilt the swivel bracket up, and then
support it using the tilt stop lever
1
.
TIP:
If the PTT unit does not operate, open the
manual valve
2
by turning it counterclock-
wise, and then tilt the swivel bracket up man-
ually.
2.
Remove the plastic ties
3
, and then pull
out the PTT motor lead
a
from the clamp
bracket (STBD).
3.
Disconnect the ground lead
4
.
4.
Remove the circlips
5
, and shaft
6
.
5.
Connect the PTT motor leads
a
to the
battery terminals to fully retract the PTT
rams.
1
2
Ram
PTT motor lead
Battery
terminal
Down
Light green (Lg)
Sky blue (Sb)
3
3
3
3
a
5
4
6
5
Lg
Sb
a
Содержание F200B
Страница 1: ...F200B FL200B F250G FL250G SERVICE MANUAL 6DX 28197 5P 11 ...
Страница 4: ......
Страница 21: ...0 16 0 Tilt rod wrench 90890 06569 Special service tool ...
Страница 23: ...1 Lower unit counter rotation model 1 19 Bracket unit 1 19 PTT unit 1 20 General tightening torque 1 21 ...
Страница 207: ...5 78 5 MEMO PTT electrical system ...
Страница 211: ...6 2 6 k Fuel rail STBD m Fuel rail PORT n Joint 7 6 f e 4 c 3 9 8 n 1 2 b d m h g k g h g 5 a Hose routing ...
Страница 314: ...7 55 POWR Power unit 17 Check that the I marks m on the VCT assembly STBD and driven sprocket STBD are aligned STBD m ...
Страница 359: ...7 100 7 MEMO Cylinder block ...
Страница 386: ...LOWR Lower unit 8 23 2 Install the rubber seal 1 1 ...
Страница 407: ...8 44 8 Shim location F250G P F R T3 T1 T2 T4 Shimming regular rotation model ...
Страница 461: ...8 98 8 Shim location FL250G F R P T3 T4 T2 T1 Shimming counter rotation model ...
Страница 473: ...8 110 8 MEMO Shimming counter rotation model ...
Страница 541: ...10 Checking the top cowling 10 15 Checking the valve clearance 10 16 Checking the water pump 10 16 ...
Страница 566: ...A 1 MEMO ...
Страница 569: ......
Страница 570: ...Jul 2011 1 CR E ...